Measurement Of The Relative Quantum Efficiency Of Hamamatsu Model R5912-20mod Photomultiplier Tubes At Liquid Argon Temperature

JOURNAL OF INSTRUMENTATION(2021)

引用 2|浏览9
暂无评分
摘要
The model R5912-20MOD photomultiplier tube(PMT) is made for cryogenic application by Hamamatsu. In this paper, we report on the measurement of relative quantum efficiency (QE) of this model PMT at liquid argon(LAr) temperature. Furthermore, a specially designed setup and relevant test method are introduced. The relative QE is measured in visible wavelengths with the PMT emerged in high purity nitrogen atmosphere. The results show that the change of QE at LAr temperature is within about 5% compared with room temperature around 420 nm. However, the QE increases about 10% in the shorter wavelength range and decreases significantly after 550 nm.
更多
查看译文
关键词
Photon detectors for UV, visible and IR photons (vacuum) (photomultipliers, HPDs, others), Photon detectors for UV, visible and IR photons (solid-state) (PIN diodes, APDs, Si-PMTs, G-APDs, CCDs, EBCCDs, EMCCDs, CMOS imagers, etc)