摘要
Abstract Funding Acknowledgements Type of funding sources: None. Introduction Transcatheter aortic valve implantation (TAVI) is a valvular replacement that has been developed as an alternative in patients with high and intermediate risk. One of the more frequent complications are new on-set conduction abnormalities. Purpose The purpose of the study was to evaluate the performance of leadless pacemakers (LPM) after TAVI and compare it with conventional pacemaker implantations (VVI- PM). Methods This was a prospective observational study that included all consecutive patients in which a TAVI and a PM was implanted during the same hospitalization (January 1 2015 to December 31 2020). Clinical, echocardiographic, ECG at implant characteristics, and related complications were described. Results From a total of 126 patients (21.3%) with PM implantation: 2 required cardiac resynchronization system, 73 DDD-PM, 29 VVI-PM, 22 LPM. Clinical and echocardiographic characteristics are described in table 1. Main follow-up was of 12 months and 22 patients (79.7%) developed AF. Electrical parameters were stable in conventional and LPM. Total mortality was of 33 patients (26.2%), there was one case of infectious endocarditis in a DDD-PM, and there were no complications in LPM patients. Conclusions. New on-set of conductions abnormalities are one of the main related complications in TAVI patients. In our study, patients with LPM had a safe performance with low complications rate. Table 1 DDD-PM (73) VVI-PM(29) LPM(22) p Age 84.2 83,1 79,4 0.1753 Men 35 (47.9%) 19 (65,5%) 12 (54,5%) 0.108746 Hypertension 67 (91.8%) 23 (79,3%) 10 (45,4%) 0.077846 Diabetes Mellitus 19 (26%) 12 (41,4%) 7 (31,8%) 0.128362 COPD 13 (17.8%) 7 (24.1%) 4 (18.2%) 0.073172 Renal insufficiency 15 (20.5%) 9 (31%) 10 (45,4%) 0.260054 AF 13 (17.8%) 27 (93.1%) 21 (95.4%) < 0.00001 Ischemic cardiomiopathy 24 (32.9%) 16 (55.2%) 7 (31.8%) 0.063504 LVEF 57.5 56 59 0.298312 Sinus Rhythm at implant 72 (98.6%) 2 (6.9%) 1 (4.5%) < 0.00001 RBBB Pre-TAVI 22 (30.1%) 3 (10.3%) 7 (31.8%) 0.06561 AF at follow-up 11 (15.1%) 28 (96.6%) 22 (100%) < 0.00001 Mortality 14 (19.2%) 14 (48.3%) 5 (22.7%) 0.002973 Complications 4 (5.5%) 1 (3.4%) 0 0.668225 Clinical, electrical and echocardiographic characteristics.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要