Comparison between capnodynamic and thermodilution method for cardiac output monitoring during major abdominal surgery: An observational study.

European journal of anaesthesiology(2021)

引用 5|浏览16
暂无评分
摘要
BACKGROUND:Cardiac output (CO) monitoring is the basis of goal-directed treatment for major abdominal surgery. A capnodynamic method estimating cardiac output (COEPBF) by continuously calculating nonshunted pulmonary blood flow has previously shown good agreement and trending ability when evaluated in mechanically ventilated pigs. OBJECTIVES:To compare the performance of the capnodynamic method of CO monitoring with transpulmonary thermodilution (COTPTD) in patients undergoing major abdominal surgery. DESIGN:Prospective, observational, method comparison study. Simultaneous measurements of COEPBF and COTPTD were performed before incision at baseline and before and after increased (+10 cmH2O) positive end-expiratory pressure (PEEP), activation of epidural anaesthesia and intra-operative events of hypovolemia and low CO. The first 25 patients were ventilated with PEEP 5 cmH2O (PEEP5), while in the last 10 patients, lung recruitment followed by individual PEEP adjustment (PEEPadj) was performed before protocol start. SETTING:Karolinska University Hospital, Stockholm, Sweden. PATIENTS:In total, 35 patients (>18 years) scheduled for major abdominal surgery with advanced hemodynamic monitoring were included in the study. MAIN OUTCOME MEASURES AND ANALYSIS:Agreement and trending ability between COEPBF and COTPTD at different clinical moments were analysed with Bland--Altman and four quadrant plots. RESULTS:In total, 322 paired values, 227 in PEEP5 and 95 in PEEPadj were analysed. Respectively, the mean COEPBF and COTPTD were 4.5 ± 1.0 and 4.8 ± 1.1 in the PEEP5 group and 4.9 ± 1.2 and 5.0 ± 1.0 l min-1 in the PEEPadj group. Mean bias (levels of agreement) and percentage error (PE) were -0.2 (-2.2 to 1.7) l min-1 and 41% for the PEEP5 group and -0.1 (-1.7 to 1.5) l min-1 and 31% in the PEEPadj group. Concordance rates during changes in COEPBF and COTPTD were 92% in the PEEP5 group and 90% in the PEEPadj group. CONCLUSION:COEPBF provides continuous noninvasive CO estimation with acceptable performance, which improved after lung recruitment and PEEP adjustment, although not interchangeable with COTPTD. This method may become a tool for continuous intra-operative CO monitoring during general anaesthesia in the future. TRIAL REGISTRATION:Clinicaltrials.gov identifier: NCT03444545.
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要