SVPWM Overmodulation Region II Control Method Based on the Chaos Ant Colony Algorithm

Journal of Electrical Engineering & Technology(2021)

引用 1|浏览1
暂无评分
摘要
The control method of space vector pulse width modulation (SVPWM) overmodulation region II has the disadvantages of a complicated process and large harmonic content. To solve these problems, this paper proposes an SVPWM overmodulation region II control method based on the chaos ant colony algorithm. Since the multiple control of the rotation angle ( θ ) in the SVPWM algorithm will bring about different implementation effects, this paper uses the chaotic ant colony algorithm to optimize the control process of θ in overmodulation region II and summarizes the θ equations in each sector to achieve the goal of suppressing the total harmonic distortion ( THD ) in the output voltage vector. Simulation and experimental results demonstrate that this method makes the amplitude of the output voltage vector relatively continuous, thereby avoiding the harmonic content caused by the voltage jump of the traditional algorithm in overmodulation region II.
更多
查看译文
关键词
SVPWM, Overmodulation, THD, Rotation angle