Biodosimetry in interventional radiology: cutaneous-based immunoassay for anticipating risks of dermatitis

Julie Bensimon Etzol, Yassine Rizzi, Theo Gateau,Joel Guersen,Bruno Pereira, Emmanuel Gouzou, Mathieu Lanaret, Oceane Grand,Caroline Bettencourt,Samuel Bouvet,Nicolas Ugolin,Sylvie Chevillard,Louis Boyer

European Radiology(2021)

Cited 2|Views2
No score
Abstract
Objectives Interventional radiology procedures expose individuals to ionizing radiation. However, existing dosimetry methods do not provide the dose effectively absorbed to the skin, and do not consider the patient’s individual response to irradiation. To resolve this lack of dosimetry data, we developed a new external irradiation biodosimetry device, DosiKit, based on the dose-dependent relationship between irradiation dose and radiation-induced H2AX protein phosphorylation in hair follicles. This new biological method was tested in Clermont-Ferrand University Hospital to evaluate the assay performances in the medical field and to estimate DosiKit sensitivity threshold. Methods DosiKit was tested over 95 patients treated with neuroradiological interventions. For each intervention, lithium fluoride thermoluminescent dosimeters (TLD) were used to measure total dose received at each hair collection point (lateral and occipital skull areas), and conventional indirect dosimetry parameters were collected with a Dosimetry Archiving and Communication System (DACS). Results Quantitative measurement of radiation-induced H2AX protein phosphorylation was performed on 174 hair samples before and after the radiation exposure and 105 samples showed a notable induction of gammaH2AX protein after the radiological procedure. According to a statistical analysis, the threshold sensitivity of the DosiKit immunoassay was estimated around 700 mGy. Conclusions With this study, we showed that DosiKit provides a useful way for mapping the actually absorbed doses, allowing to identify patients overexposed in interventional radiology procedures, and thus for anticipating risk of developing dermatitis. Key Points • DosiKit is a new external irradiation biodosimetry device, based on the dose-dependent relationship between irradiation dose and radiation-induced H2AX protein phosphorylation in hair follicles. • DosiKit was tested over 95 patients treated with neuroradiological interventions. • The threshold sensitivity of the DosiKit immunoassay was estimated around 700 mGy and DosiKit provides a useful way for mapping the actually absorbed doses.
More
Translated text
Key words
Radiation protection, Interventional radiology, Radiation dosimeters, Biology
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined