Comparison Of Myoglobin Clearance In Three Types Of Blood Purification Modalities

THERAPEUTIC APHERESIS AND DIALYSIS(2021)

Cited 3|Views8
No score
Abstract
Myoglobin, which can cause acute kidney injury, has a relatively high molecular weight and is poorly cleared by diffusion. We compared and examined myoglobin clearance by changing the blood purification membrane and modality in patients with a myoglobin blood concentration >= 1000 ng/ml. We retrospectively analyzed three patient groups based on the following three types of continuous hemofiltration (CHF): AN69ST membrane, polymethylmethacrylate (PMMA) membrane, and high-flow hemodiafiltration (HDF) with increased dialysate flow rate using the PMMA membrane. There was no significant difference in clearance in CHF between AN69ST and PMMA membranes. However, the high-flow HDF group showed the highest myoglobin clearance (p = 0.003). In the PMMA membrane, changing the treatment modality to high-flow HDF increased clearance above the theoretical value, possibly due to internal filtration. To remove myoglobin by kidney replacement therapy from patients with hypermyoglobinemia, a modality such as high-flow HDF would be desirable.
More
Translated text
Key words
hemofiltration, modality, myoglobin, polyacrylonitrile, polymethylmethacrylate