Validity of the Spanish-Language Patient Health Questionnaires 2 and 9

JAMA NETWORK OPEN(2023)

Cited 0|Views3
No score
Abstract
Importance Reliable screening for major depressive disorder (MDD) relies on valid and accurate screening tools.Objective To examine the validity, accuracy, and reliability of the Spanish-language Patient Health Questionnaires 2 and 9 (PHQ-2 and PHQ-9) to screen for MDD.Data Sources PubMed, Web of Science, Embase, and PsycINFO from data initiation through February 27, 2023.Study SelectionEnglish- and Spanish-language studies evaluating the validity of the Spanish-language PHQ-2 or PHQ-9 in screening adults for MDD compared with a standardized clinical interview (gold standard). Search terms included PHQ-2, PHQ-9, depression, and Spanish.Data Extraction and SynthesisTwo reviewers performed abstract and full-text reviews, data extraction, and quality assessment. Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) guidelines were followed. Random-effects meta-analyses of sensitivity, specificity, and area under the curve (AUC) were performed. Internal consistency was evaluated using Cronbach alpha and McDonald psi.Main Outcomes and MeasuresTest accuracy and internal consistency. The PHQ-2 is composed of the first 2 questions of the PHQ-9 (targeting core depression symptoms of depressed mood and anhedonia; a score of 3 or higher (score range, 0-6) is generally considered a positive depression screen. If a patient screens positive with the PHQ-2, a follow-up assessment with the PHQ-9 and a clinical diagnostic evaluation are recommended. Once depression is diagnosed, a PHQ-9 score of 10 or higher (score range, 0-27) is often considered an acceptable threshold for treating depression.Results Ten cross-sectional studies involving 5164 Spanish-speaking adults (mean age range, 34.1-71.8 years) were included; most studies (n = 8) were in primary care settings. One study evaluated the PHQ-2, 7 evaluated the PHQ-9, and 2 evaluated both the PHQ-2 and PHQ-9. For the PHQ-2, optimal cutoff scores ranged from greater than or equal to 1 to greater than or equal to 2, with an overall pooled sensitivity of 0.89 (95% CI, 0.81-0.95), overall pooled specificity of 0.89 (95% CI, 0.81-0.95), and overall pooled AUC of 0.87 (95% CI, 0.83-0.90); Cronbach alpha was 0.71 to 0.75, and McDonald psi was 0.71. For the PHQ-9, optimal cutoff scores ranged from greater than or equal to 5 to greater than or equal to 12, with an overall pooled sensitivity of 0.86 (95% CI, 0.82-0.90), overall pooled specificity of 0.80 (95% CI, 0.75-0.85), and overall pooled AUC of 0.88 (95% CI, 0.87-0.90); Cronbach alpha was 0.78 to 0.90, and McDonald psi was 0.79 to 0.90. Four studies were considered to have low risk of bias; 6 studies had indeterminate risk of bias due to a lack of blinding information.Conclusions and Relevance In this systematic review and meta-analysis, limited available evidence supported the use of the Spanish-language PHQ-2 and PHQ-9 in screening for MDD, but optimal cutoff scores varied greatly across studies, and few studies reported on blinding schemes. These results suggest that MDD should be considered in Spanish-speaking individuals with lower test scores. Given the widespread clinical use of the tools and the heterogeneity of existing evidence, further investigation is needed.
More
Translated text
Key words
health,patient,spanish-language
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined