当发生母线区外故障,故障支路的非故障相电流互感器(CT)出现饱和时,为防止母差保护误动作,提出基于电流分布系数识别故障支路非故障相饱和的方法,识别出非故障相饱和后闭锁母差保护.采用该方法计算母线区外故障时电源支路的故障相电流分布系数及“母线二次故障”时电源支路的“二次故障”相电流分布系数,并对比两者计算结果.若计算结果不一致,说明“二次故障”为非故障相饱和;若计算结果一致,说明“二次故障”为母线区内或区外故障.实时数字仿真(RTDS)结果表明,在不降低母差保护动作速度的前提下,该方法能快速准确识别故障支路非故障相饱和,可靠防止母差保护误动.