Rigid and Deformable Image Registration for Radiation Therapy: A Self-Study Evaluation Guide for NRG Oncology Clinical Trial Participation.

Practical radiation oncology(2021)

Cited 32|Views9
No score
Abstract
PURPOSE:The registration of multiple imaging studies to radiation therapy computed tomography simulation, including magnetic resonance imaging, positron emission tomography-computed tomography, etc. is a widely used strategy in radiation oncology treatment planning, and these registrations have valuable roles in image guidance, dose composition/accumulation, and treatment delivery adaptation. The NRG Oncology Medical Physics subcommittee formed a working group to investigate feasible workflows for a self-study credentialing process of image registration commissioning. METHODS AND MATERIALS:The American Association of Physicists in Medicine (AAPM) Task Group 132 (TG132) report on the use of image registration and fusion algorithms in radiation therapy provides basic guidelines for quality assurance and quality control of the image registration algorithms and the overall clinical process. The report recommends a series of tests and the corresponding metrics that should be evaluated and reported during commissioning and routine quality assurance, as well as a set of recommendations for vendors. The NRG Oncology medical physics subcommittee working group found incompatibility of some digital phantoms with commercial systems. Thus, there is still a need to provide further recommendations in terms of compatible digital phantoms, clinical feasible workflow, and achievable thresholds, especially for future clinical trials involving deformable image registration algorithms. Nine institutions participated and evaluated 4 commonly used commercial imaging registration software and various versions in the field of radiation oncology. RESULTS AND CONCLUSIONS:The NRG Oncology Working Group on image registration commissioning herein provides recommendations on the use of digital phantom/data sets and analytical software access for institutions and clinics to perform their own self-study evaluation of commercial imaging systems that might be employed for coregistration in radiation therapy treatment planning and image guidance procedures. Evaluation metrics and their corresponding values were given as guidelines to establish practical tolerances. Vendor compliance for image registration commissioning was evaluated, and recommendations were given for future development.
More
Translated text
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined