Using Millimeter-Sized Carbon-Deuterium Foils For High-Precision Deuterium-Tritium Neutron Spectrum Measurements In Direct-Drive Inertial Confinement Fusion At The Omega Laser Facility

REVIEW OF SCIENTIFIC INSTRUMENTS(2021)

引用 2|浏览15
暂无评分
摘要
Millimeter-sized CD foils fielded close (order mm) to inertial confinement fusion (ICF) implosions have been proposed as a game-changer for improving energy resolution and allowing time-resolution in neutron spectrum measurements using the magnetic recoil technique. This paper presents results from initial experiments testing this concept for direct drive ICF at the OMEGA Laser Facility. While the foils are shown to produce reasonable signals, inferred spectral broadening is seen to be high (similar to 5 keV) and signal levels are low (by similar to 20%) compared to expectation. Before this type of foil is used for precision experiments, the foil mount must be improved, oxygen uptake in the foils must be better characterized, and impact of uncontrolled foil motion prior to detection must be investigated.