Objectives: To study the test-retest reliability and measurement error, construct validity, responsiveness, interpretability, and floor/ceiling effects of a Patient-Reported Outcomes Measurement Information System (PROMIS) short form designed to measure physical function in geriatric rehabilitation patients (PROMIS-PF-GR). Design: Prospective cohort. Setting and Participants: Inpatient geriatric rehabilitation patients. Methods: We evaluated the test-retest reliability by re-administering PROMIS-PF-GR 3 to 5 days after the admission measurement. The intraclass correlation coefficient (ICC) was calculated to determine test-retest reliability; an ICC of >= 0.70 was considered sufficient. Measurement error was established by calculating the standard error of measurement and smallest detectable change. Construct validity and responsiveness were determined by testing a priori formulated hypotheses (criterion: >= 75% hypothesis not rejected). Interpretability was evaluated by calculating the minimal important change using predictive modeling and a global rating as criterion for change. Floor/ceiling effects were established by calculating the percentage patients with the minimum/maximum raw score (criterion: <= 15%) at admission and discharge. Results: A total of 207 patients participated in the study [mean +/- standard deviation age (80 +/- 8.3 years), 58% female]. More than one-half of patients (56%) reported to be improved during rehabilitation. The ICC was 0.79 (95% confidence interval 0.70-0.84), the standardized error of measurement was 3.8, and the smallest detectable change 10.6. None of the 4 hypotheses for construct validity were rejected; 2 out of 5 hypotheses for responsiveness were rejected. The minimal important change was 8.0 (95% confidence interval 4.1-12.5). No floor/ceiling effects were found. Conclusions and Implications: The PROMIS-PG-GR showed sufficient test-retest reliability, measurement error, and construct validity. We did not find sufficient evidence for responsiveness, which may be due to the unexplained weak correlation between the PROMIS change score and the Global Rating Scale. We still recommend the use the PROMIS-PG-GR for measuring self-reported physical function in geriatric rehabilitation. (C) 2021 The Authors. Published by Elsevier Inc. on behalf of AMDA - The Society for Post-Acute and Long-Term Care Medicine.
更多
查看译文
关键词
Geriatric rehabilitation,patient-reported outcome measure,patient-centered care,post-acute care,PROMIS,physical function,geriatric patients
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要