Ultrasonic Thermometric Measurement System For Solid Rocket Combustion Chambers

ULTRASONICS(2021)

Cited 4|Views10
No score
Abstract
Solid rocket motor (SRM) temperature is an important physical parameter for which there is no reliable in situ measurement device, apart from a thermocouple, for such a high temperature environment apart. In this study, an ultrasonic temperature measurement system was designed with an iridium-rhodium-40% alloy waveguide. Laboratory experiments showed that the device obtained ultrasonic signals up to 1800 degrees C with a temperature fitting curve from room temperature to 1800 degrees C. The thermometer also operated stably under high temperature and produced a repeatable calibration curve, at 97% repeatability. An error band was obtained with 95% confidence. At temperatures above 1000 degrees C, sensitivity gradually increased to a maximum of 0.0035 mu s/degrees C. A corresponding application structure was established for an SRM before subjecting the sensor to a temperature test experiment. The temperature-time curve obtained detected a peak temperature at 1744 degrees C.y
More
Translated text
Key words
Ultrasonic thermometry, Solid Rocket Motor (SRM), Ultrasonic velocity, Iridium rhodium alloy, Temperature