ObjectiveTo evaluate the accuracy of initial computed tomography (CT) interpretations made by radiology residents during nightshifts in the emergency department. MethodsPreliminary CT reports performed by radiology residents during 120 consecutive nightshifts (08:30 pm to 08:30 am) were reviewed, attendings' final interpretation being the reference standard. Nightshifts were divided into four consecutive periods of 3 hours. Major misinterpretations were related to potentially life-threatening conditions if not treated immediately after CT. The rate of misinterpretations was calculated for all CT examinations, separately for nightshift's periods and for residents' training years. ResultsMisinterpretations were recorded in 155 (7.4%) of 2102 CT examinations, 0.6% (13/2102) were major. There were 2.2% (4/186) major misinterpretations that occurred during the last period of the nightshift versus 0.4% (9/1916) during the first periods of the night (P < 0.05). Of all misinterpretations, 8.5% (130/1526) were made by third- and fourth-year residents and 4.3% (25/576) by fifth-year residents (P < 0.005). ConclusionsMajor misinterpretations occur at the end of the nightshift, which may be explained by the fatigue effect. The rate of misinterpretations is lower among fifth-year residents, which may be related to their prior experience in reading emergency cases.