Identification And Correction Method Of Nuclear Detector Pulse Forming Pile-Up

Siyan Du,Jia Liu, Fengfan Yang,Jinfan Chang

ENERGY REPORTS(2020)

引用 2|浏览3
暂无评分
摘要
Gaussian forming has good time, response and SNR, Gaussian shaping is widely used in nuclear signal processing because of its simple realization and good comprehensive performance. When working in high counting rate environment, the output pulse signal of nuclear detector often appears pile-up phenomenon, which leads to the nuclear spectrum measurement system cannot accurately extract the pulse amplitude, and then the energy spectrum measurement error. In order to solve this problem, a method of pulse pile-up identification and correction is proposed. A test system consisting of signal generator, detector, communication circuit and oscilloscope is designed. Experiments show that this method can accurately identification and correct the pile-up waveform., and increase count rate by 3%-30% compared with the traditional method. (C) 2020 The Author(s). Published by Elsevier Ltd. This
更多
查看译文
关键词
Nuclear detector, CR-RC circuit, Pulse pileup identification, Pulse pileup correction
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要