Evaluating Accuracy of Plain Magnetic Resonance Imaging or Arthrogram versus Wrist Arthroscopy in the Diagnosis of Scapholunate Interosseous Ligament Injury

Nardeen Kader,Mohammed Shoaib Arshad, Pawan K. Chajed, Daoud Makki,Kiran Naikoti,David Temperley,S. Raj Murali

Journal of Hand and Microsurgery(2020)

引用 0|浏览3
暂无评分
摘要
Introduction Scapholunate interosseous ligament injury (SLIL) is the most common cause of wrist instability and a cause of morbidity in a proportion of patients with wrist injuries. Aim To evaluate the accuracy of plain magnetic resonance imaging (MRI) and MR arthrogram (MRA) in the diagnosis of SLIL injury against the existing gold standard-wrist arthroscopy. Materials and Methods We retrospectively reviewed 108 cases by comparing MRI/MRA reports and their wrist arthroscopy operation notes. Results Overall MRI sensitivity to SLIL injuries was 38.5% (91.0% specificity). When broken down into plain MRI and MRA the results were: plain MRI sensitivity = 19.2% (91.4% specificity) and MRA sensitivity = 57.7% (90.5% specificity). Conclusion Neither MRI nor MRA scanning is sensitive enough compared with the gold standard. Positive predictive value remains too low (62.5 and 88.2%, respectively) to consider bypassing diagnostic arthroscopy and treating surgically. The negative predictive value (60.4 and 63.6%, respectively) is inadequate to confirm exclusion of injury from MRI results alone.
更多
查看译文
关键词
scapholunate ligament injury, diagnosis, evaluation, magnetic resonance imaging, arthroscopy