Influence of the Installation Position of Submersible Pumps on Deposition Characteristics in Prefabricated Pumping Stations.

SYMMETRY-BASEL(2020)

Cited 1|Views7
No score
Abstract
Based on the discrete phase model (DPM), solid-liquid two-phase flow calculation, particle settling theory and MATLAB image processing technology, the influence of the installation position of submersible pumps on the deposition characteristics in a cylinder-type prefabricated pumping station was studied, and two performance indices, the deposition rate and area ratio of the easy deposition region were proposed. The results show that the area ratio and deposition rate of the easy deposition region increase as the suspension height increases. The discharge effect is best when the suspension height is 0.1H(0), however, at this time the inlet bias of the pump is larger, which is not conducive to the smooth operation of submersible pumps. The area ratio and deposition rate of the easy deposition region gradually increase with the increase in the interval of the pumps. As the center distance increases, the area ratio and deposition rate of the easy deposition region basically decreases first and then increases, and reach the minimum at 0.1Rand 0R, respectively.
More
Translated text
Key words
prefabricated pumping station,deposition characteristics,area ratio of easy deposition region,deposition rate
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined