We report on a comparison experiment between a low dc current source based on the capacitance-voltage method, and an ultrastable-low noise current amplifier (ULCA). The two instruments can be calibrated independently using different methods and traceability paths. The agreement is of a few parts in 10(5) for currents close to 10pA and 100pA; the residual deviation might be related to the frequency dependence of the capacitance employed in the source.