Wearable Analytical Platform With Enzyme-Modulated Dynamic Range For The Simultaneous Colorimetric Detection Of Sweat Volume And Sweat Biomarkers

ACS SENSORS(2021)

引用 38|浏览15
暂无评分
摘要
In this manuscript, we introduce a wearable analytical platform that simultaneously measures the concentration of sweat lactate and sample volume. It contains two sensors entirely made of filter paper that can be easily affixed on the skin with medical-grade tape. The lactate biosensor features a unique signal modulation mechanism that enables fine-tuning the dynamic range. It consists of adding a competitive enzyme inhibitor in different reservoirs. Thanks to this, it is possible to choose between a very low limit of detection (0.06 mM) and a linear response in the physiological concentration range (10-30 mM). The sweat volume sensor was obtained by adding a reservoir containing gold nanoparticles. As the wearer sweats, the nanoparticles are carried through a paper channel. This is used to gauge the volume of sample by measuring the distance traveled by the nanoprobes. Using fine-tuned lactate biosensors and combining them with the volume sensors allowed us to quantify variations in the levels of sweat lactate independently of the wearer's sweat rate during an exercise routine. The platform design can be customized to meet the end user's needs, which makes it ideal for developing a wide array of disposable wearable biosensors.
更多
查看译文
关键词
paper-based analytical device, lactate, enzyme, wearable biosensor, nanoparticle, sweat