Background and PurposeThe Italian National Center of Oncological Hadrontherapy (CNAO) has applied dose constraints for carbon ion RT (CIRT) as defined by Japan's National Institute of Radiological Sciences (NIRS). However, these institutions use different models to predict the relative biological effectiveness (RBE). CNAO applies the Local Effect Model I (LEM I), which in most clinical situations predicts higher RBE than NIRS's Microdosimetric Kinetic Model (MKM). Equal constraints therefore become more restrictive at CNAO. Tolerance doses for the brainstem have not been validated for LEM I-weighted dose (D (LEM I)). However, brainstem constraints and a Normal Tissue Complication Probability (NTCP) model were recently reported for MKM-weighted dose (D (MKM)), showing that a constraint relaxation to D MKM|0.7 cm(3) <30 Gy (RBE) and D MKM|0.1 cm(3) <40 Gy (RBE) was feasible. The aim of this work was to evaluate the brainstem NTCP associated with CNAO's current clinical practice and to propose new brainstem constraints for LEM I-optimized CIRT at CNAO.Material and MethodsWe reproduced the absorbed dose of 30 representative patient treatment plans from CNAO. Subsequently, we calculated both D (LEM I) and D (MKM), and the relationship between D (MKM) and D (LEM I) for various brainstem dose metrics was analyzed. Furthermore, the NTCP model developed for D (MKM) was applied to estimate the NTCPs of the delivered plans.ResultsThe translation of CNAO treatment plans to D (MKM) confirmed that the former CNAO constraints were conservative compared with D (MKM) constraints. Estimated NTCPs were 0% for all but one case, in which the NTCP was 2%. The relationship D (MKM)/D (LEM I) could be described by a quadratic regression model which revealed that the validated D (MKM) constraints corresponded to D LEM I|0.7 cm(3) <41 Gy (RBE) (95% CI, 38-44 Gy (RBE)) and D LEM I|0.1 cm(3) <49 Gy (RBE) (95% CI, 46-52 Gy (RBE)).ConclusionOur study demonstrates that RBE-weighted dose translation is of crucial importance in order to exchange experience and thus harmonize CIRT treatments globally. To mitigate uncertainties involved, we propose to use the lower bound of the 95% CI of the translation estimates, i.e., D LEM I|0.7 cm(3) <38 Gy (RBE) and D LEM I|0.1 cm(3) <46 Gy (RBE) as brainstem dose constraints for 16 fraction CIRT treatments optimized with LEM I.
更多
查看译文
关键词
carbon ion radiotherapy, normal tissue complication probability, dose constraints, local effect model, microdosimetric kinetic model, relative biological effectiveness (RBE), brainstem tolerance
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要