Chrome Extension
WeChat Mini Program
Use on ChatGLM

Impella percutaneous left ventricular assist device as mechanical circulatory support for cardiogenic shock: A retrospective analysis from a tertiary academic medical center

Shayan Nabavi Nouri, Waqas Malick, Amirali Masoumi, Justin A. Fried, Veli K. Topkara, Michael I. Brener, Yousif Ahmad, Megha Prasad, LeRoy E. Rabbani, Koji Takeda, Dimitrios Karmpaliotis, Jeffrey W. Moses, Martin B. Leon, Ajay J. Kirtane, A. Reshad Garan

CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS(2022)

Cited 5|Views55
No score
Abstract
Objectives To describe hemodynamic efficacy and clinical outcomes of Impella percutaneous left ventricular assist device (pLVAD) in patients with cardiogenic shock (CS). Background Percutaneous LVADs are increasingly used in CS management. However, device-related outcomes and optimal utilization remain active areas of investigation. Methods All CS patients receiving pLVAD as mechanical circulatory support (MCS) between 2011 and 2017 were identified. Clinical characteristics and outcomes were analyzed. A multivariable logistic regression model was created to predict MCS escalation despite pLVAD. Outcomes were compared between early and late implantation. Results A total of 115 CS patients (mean age 63.6 +/- 13.8 years; 69.6% male) receiving pLVAD as MCS were identified, the majority with CS secondary to acute myocardial infarction (AMI; 67.0%). Patients experienced significant cardiac output improvement (median 3.39 L/min to 3.90 L/min, p = .002) and pharmacological support reduction (median vasoactive-inotropic score [VIS] 25.4 to 16.4, p = .049). Placement of extracorporeal membrane oxygenation (ECMO) occurred in 48 (41.7%) of patients. Higher pre-pLVAD VIS was associated with subsequent MCS escalation in the entire cohort and AMI subgroup (OR 1.27 [95% CI 1.02-1.58], p = .034 and OR 1.72 [95% CI 1.04-2.86], p = .035, respectively). Complications were predominantly access site related (bleeding [9.6%], vascular injury [5.2%], and limb ischemia [2.6%]). In-hospital mortality was 57.4%, numerically greater survival was noted with earlier device implantation. Conclusions Treatment with pLVAD for CS improved hemodynamic status but did not uniformly obviate MCS escalation. Mortality in CS remains high, though earlier device placement for appropriately selected patients may be beneficial.
More
Translated text
Key words
acute myocardial infarction,cardiogenic shock,ECMO,Impella,mechanical circulatory support
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined