Rigorous-two-Steps scheme of TRIPOLI-4 (R) Monte Carlo code validation for shutdown dose rate calculation

EPJ Web of Conferences(2017)

引用 5|浏览2
暂无评分
摘要
After fission or fusion reactor shutdown the activated structure emits decay photons. For maintenance operations the radiation dose map must be established in the reactor building. Several calculation schemes have been developed to calculate the shutdown dose rate. These schemes are widely developed in fusion application and more precisely for the ITER tokamak. This paper presents the rigorous-two-steps scheme implemented at CEA. It is based on the TRIPOLI-4 (R) Monte Carlo code and the inventory code MENDEL. The ITER shutdown dose rate benchmark has been carried out, results are in a good agreement with the other participant.