Extraction of many H- Beamlets from Ion Source NIO1

AIP Conference Proceedings(2018)

Cited 0|Views55
No score
Abstract
After installation of Mo liners in the source NIO1 (Negative Ion Optimization phase 1), hydrogen plasmas in a continuous regime operation (much longer than one hour) are routinely maintained, with more than 1 kW rf power and 0.5 Pa pressure, allowing a systematic investigation of pure H- volume effect, which requests a much lower acceleration voltage V-s congruent to 12 kV than future Cs operations at V-s congruent to 60 kV. A new extraction grid EG was installed (replacing some eroded insulators) and preliminary beam images are compared to old EG ones, discussing effects of different deflection field strength and need of intermediate values. Large improvements in beam diagnostics and the effect of installation of a cryogenic pump are also reported.