Bispectral Index Monitoring With Density Spectral Array For Delirium Detection

Alice Luo,Susan Muraida,Dana Pinchotti, Elizabeth Richardson,Enstin Ye, Bryce Hollingsworth, Alexander Win,Orrin Myers,Jens Langsjoen, Emiliano Valles,Arpad Zolyomi,Davin K Quinn

JOURNAL OF THE ACADEMY OF CONSULTATION-LIAISON PSYCHIATRY(2021)

引用 3|浏览7
暂无评分
摘要
Background: Delirium in hospitalized patients often goes undetected. Cerebral state monitors, which measure limited-channel electroencephalography, have shown potential for improving delirium detection. Objective: The aim of this study was to compare an FDA-approved cerebral state monitor, bispectral index monitoring with density spectral array (DSA), for delirium identification with clinical screening methods. Methods: Hospitalized patients receiving psychiatric consultation were assessed for delirium using the 3-minute Diagnostic Interview for Confusion Assessment Method (3D-CAM) and underwent bispectral index monitor + DSA monitoring. Visual inspection of frequency band power of the DSA was performed by 2 trained independent raters. Average hue values were calculated for each frequency band using image analysis software as the device did not allow for extraction of raw electroencephalography data. Delirious versus nondelirious group averages, sensitivity, specificity, and area under the curve were calculated for significant DSA variables and the 3D-CAM. Results: In an initial cohort of 43 patients, visual ratings of the DSA were not associated with delirium (P > 0.1). In a larger cohort of 123 subjects, multiple band hue ratios were associated with delirium, although none survived correction for multiple comparisons. In a subgroup of 74 non-neurological patients, low theta/low delta ratio was significantly associated with delirium (P = 0.001) (sensitivity/specificity/area under the curve: 83%/70%/0.757; 3D-CAM: 67%/77%/0.717; paired-sample area under the curve difference: -0.040, P = 0.68). In 21 patients with dementia, low theta power demonstrated significantly greater sensitivity/specificity/area under the curve of 83%/78%/0.824, whereas 3D-CAM achieved 50%/78%/0.639 (P = 0.04). Conclusion: Bispectral index monitor + DSA was similar to 3D-CAM for detecting delirium in hospitalized patients with and without neurological disorders, and was significantly more accurate in patients with dementia. More studies are needed to validate the use of cerebral state monitors for quantitative delirium detection.
更多
查看译文
关键词
delirium, bispectral index monitoring, density spectral array
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要