Application of iodixanol in gemstone spectral imaging with low CT dosage

Junping Song,Nianlong Liu,Yuhuang Wang,Bo Yang, Shen Wenrong,Liuli Sheng

Chinese Journal of Primary Medicine and Pharmacy(2018)

引用 0|浏览13
暂无评分
摘要
Objective To study the application value of iodixanol in gemstone spectral imaging with low CT dosage. Methods Forty hundred and twenty-six cancer patients with normal kidney function were selected.All of them underwent enhanced gemstone spectral CT scan with low dosage.They were individed into two groups with random number table, including observation group(n=213) and control group(n=213). The observation group was injected isotonic iodixanol(270mgI/mL) intravenously, while the control group was injected hypertronic iohexol (350mgI/mL) intravenously.With the same injection speed, the acute adverse reaction within 1h and delayed adverse reaction between 1h~7d were recorded.Meanwhile, the changes of Scr and Ccr, the occurrence rate of contrast-induced nephropathy(CIN) and short-term prognosis were also recorded. Results Fifty-three patients occurred acute adverse reaction, among them 18 cases(8.45%) were in the observation group, 35 cases(16.43%) were in the control group, there was statistically significant difference between the two groups(χ2=10.791, P 0.05). Conclusion The intravenous injection of iodixanol can reduce the occurrence of acute adverse reaction, will not increase the incidence of CIN.It can be used safely. Key words: Tomography, X-ray computed; Iodixanol; Contrast media
更多
查看译文
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要