Safety and cost-effectiveness of individualised screening for diabetic retinopathy: the ISDR open-label, equivalence RCT

Diabetologia(2020)

引用 20|浏览23
暂无评分
摘要
Aims/hypothesis Using variable diabetic retinopathy screening intervals, informed by personal risk levels, offers improved engagement of people with diabetes and reallocation of resources to high-risk groups, while addressing the increasing prevalence of diabetes. However, safety data on extending screening intervals are minimal. The aim of this study was to evaluate the safety and cost-effectiveness of individualised, variable-interval, risk-based population screening compared with usual care, with wide-ranging input from individuals with diabetes. Methods This was a two-arm, parallel-assignment, equivalence RCT (minimum 2 year follow-up) in individuals with diabetes aged 12 years or older registered with a single English screening programme. Participants were randomly allocated 1:1 at baseline to individualised screening at 6, 12 or 24 months for those at high, medium and low risk, respectively, as determined at each screening episode by a risk-calculation engine using local demographic, screening and clinical data, or to annual screening (control group). Screening staff and investigators were observer-masked to allocation and interval. Data were collected within the screening programme. The primary outcome was attendance (safety). A secondary safety outcome was the development of sight-threatening diabetic retinopathy. Cost-effectiveness was evaluated within a 2 year time horizon from National Health Service and societal perspectives. Results A total of 4534 participants were randomised. After withdrawals, there were 2097 participants in the individualised screening arm and 2224 in the control arm. Attendance rates at first follow-up were equivalent between the two arms (individualised screening 83.6%; control arm 84.7%; difference −1.0 [95% CI −3.2, 1.2]), while sight-threatening diabetic retinopathy detection rates were non-inferior in the individualised screening arm (individualised screening 1.4%, control arm 1.7%; difference −0.3 [95% CI −1.1, 0.5]). Sensitivity analyses confirmed these findings. No important adverse events were observed. Mean differences in complete case quality-adjusted life-years (EuroQol Five-Dimension Questionnaire, Health Utilities Index Mark 3) did not significantly differ from zero; multiple imputation supported the dominance of individualised screening. Incremental cost savings per person with individualised screening were £17.34 (95% CI 17.02, 17.67) from the National Health Service perspective and £23.11 (95% CI 22.73, 23.53) from the societal perspective, representing a 21% reduction in overall programme costs. Overall, 43.2% fewer screening appointments were required in the individualised arm. Conclusions/interpretation Stakeholders involved in diabetes care can be reassured by this study, which is the largest ophthalmic RCT in diabetic retinopathy screening to date, that extended and individualised, variable-interval, risk-based screening is feasible and can be safely and cost-effectively introduced in established systematic programmes. Because of the 2 year time horizon of the trial and the long time frame of the disease, robust monitoring of attendance and retinopathy rates should be included in any future implementation. Trial registration ISRCTN 87561257 Funding The study was funded by the UK National Institute for Health Research. Graphical abstract
更多
查看译文
关键词
Diabetic retinopathy,Individualised,Personalised,Risk-based,Screening,Systematic,Variable interval
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要