Influences Of Fusion Neutrons On Compton Suppressed Gamma-Spectrum Analyses At The Hl-2a Tokamak

APPLIED RADIATION AND ISOTOPES(2020)

引用 0|浏览48
暂无评分
摘要
The newly-built Compton suppression system at the HL-2A tokamak works in a harsh fusion neutron field especially when the second neutral beam injection system is put into application. The present paper performed Geant4 simulations to study the influences of fusion neutrons on Compton suppressed gamma-spectrum analyses. The simulation data show that the influence of fusion neutrons on suppressed gamma-spectrum shape is limited, while the influence on detection efficiencies is considerable. Consequently, the changes of detection efficiencies caused by the coexisting neutrons must be taken into account in the subsequent gamma-spectrum analyses. Hence, the empirical formulas of gamma-ray detection efficiencies of the Compton suppression system, which had considered the influences of fusion neutrons, were put forward and then applied to unfold the experimental gamma-spectra. This work lays a superior foundation for the further analyses of the Compton suppressed gamma-spectra at the HL-2A tokamak.
更多
查看译文
关键词
Gamma spectrum analyses, Compton suppression system, Geant4 simulation, Fusion neutrons, gamma-ray diagnostic