Development Of An Electrochemical Immunosensor For Specific Detection Of Visceral Leishmaniasis Using Gold-Modified Screen-Printed Carbon Electrodes

Beatriz R. Martins, Yanne O. Barbosa, Cristhianne M. R. Andrade, Loren Q. Pereira, Guilherme F. Simao, Carlo J. De Oliveira,Dalmo Correia, Robson T. S. Oliveira Jr,Marcos Da Silva,Anielle C. A. Silva, Noelio O. Dantas,Virmondes Rodrigues Jr, Rodrigo A. A. Munoz,Renata P. Alves-Balvedi

BIOSENSORS-BASEL(2020)

Cited 19|Views11
No score
Abstract
Visceral leishmaniasis is a reemerging neglected tropical disease with limitations for its diagnosis, including low concentration of antibodies in the serum of asymptomatic patients and cross-reactions. In this context, this work proposes an electrochemical immunosensor for the diagnosis of visceral leishmaniasis in a more sensitive way that is capable of avoiding cross-reaction with Chagas disease (CD). CrudeLeishmania infantumantigens tested in the enzyme-linked immunosorbent assay (ELISA) were methodologically standardized to best engage to the sensor. The antibodies anti-Trypanosoma cruziand anti-Leishmaniasp. Present in serum from patients with diverse types of CD or leishmaniasis were chosen. A screen-printed carbon electrode modified with gold nanoparticles was the best platform to guarantee effective adsorption of all antigens so that the epitope of specific recognition for leishmaniasis occurred efficiently and without cross-reaction with the evaluated CD. The current peaks reduced linearly after the recognition, and still were able to notice the discrimination between different kinds of diseases (digestive, cardiac, undetermined Chagas/acute and visceral chronic leishmaniasis). Comparative analyses with ELISA were performed with the same groups, and a low specificity (44%) was verified due to cross-reactions (high number of false positives) on ELISA tests, while the proposed immunosensor presented high selectivity and specificity (100%) without any false positives or false negatives for the serum samples from isolated patients with different types of CD and visceral leishmaniasis. Furthermore, the biosensor was stable for 5 days and presented a detection limit of 200 ng mL(-1).
More
Translated text
Key words
electrochemical biosensor,visceral leishmaniasis,Chagas disease,gold nanoparticles,point-of-care,portable analysis
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined