Sensitivity of the NEXT experiment to Xe-124 double electron capture

G. Martínez-Lema, M. Martínez-Vara,M. Sorel,C. Adams,V. Álvarez,L. Arazi, I. J. Arnquist,C. D. R Azevedo,K. Bailey, F. Ballester, J. M. Benlloch-Rodríguez, F. I. G. M. Borges, N. Byrnes, S. Cárcel, J. V. Carrión,S. Cebrián, E. Church, C. A. N. Conde,T. Contreras,G. Díaz,J. Díaz, M. Diesburg,J. Escada, R. Esteve, R. Felkai, A. F. M. Fernandes, L. M. P. Fernandes, P. Ferrario,A. L. Ferreira,E. D. C. Freitas, J. Generowicz,S. Ghosh, A. Goldschmidt,J. J. Gómez-Cadenas, D. González-Díaz, R. Guenette,R. M. Gutiérrez,J. Haefner,K. Hafidi, J. Hauptman,C. A. O. Henriques,J. A. Hernando Morata,P. Herrero, V. Herrero, Y. Ifergan,S. Johnston,B. J. P. Jones,M. Kekic, L. Labarga, A. Laing, P. Lebrun, N. López-March,M. Losada, R. D. P. Mano, J. Martín-Albo,A. Martínez, A. D. McDonald,F. Monrabal,C. M. B. Monteiro,F. J. Mora,J. Muñoz Vidal, P. Novella, D. R. Nygren,B. Palmeiro, A. Para,J. Pérez, M. Querol, A. B. Redwine,J. Renner,J. Repond, S. Riordan,L. Ripoll,Y. Rodríguez García,J. Rodríguez, L. Rogers, B. Romeo, C. Romo-Luque, F. P. Santos,J. M. F. dos Santos,A. Simón, C. Sofka, T. Stiegler, J. F. Toledo, J. Torrent, A. Usón,J. F. C. A. Veloso, R. Webb, R. Weiss-Babai, J. T. White, K. Woodruff,N. Yahlali

JOURNAL OF HIGH ENERGY PHYSICS(2021)

引用 1|浏览84
暂无评分
摘要
bstract Double electron capture by proton-rich nuclei is a second-order nuclear process analogous to double beta decay. Despite their similarities, the decay signature is quite different, potentially providing a new channel to measure the hypothesized neutrinoless mode of these decays. The Standard-Model-allowed two-neutrino double electron capture (2 νEC EC ) has been predicted for a number of isotopes, but only observed in 78 Kr, 130 Ba and, recently, 124 Xe. The sensitivity to this decay establishes a benchmark for the ultimate experimental goal, namely the potential to discover also the lepton-number-violating neutrinoless version of this process, 0 νEC EC . Here we report on the current sensitivity of the NEXT-White detector to 124 Xe 2 νEC EC and on the extrapolation to NEXT-100. Using simulated data for the 2 νEC EC signal and real data from NEXT-White operated with 124 Xe-depleted gas as background, we define an optimal event selection that maximizes the NEXT-White sensitivity. We estimate that, for NEXT-100 operated with xenon gas isotopically enriched with 1 kg of 124 Xe and for a 5-year run, a sensitivity to the 2 νEC EC half-life of 6 × 10 22 y (at 90% confidence level) or better can be reached.
更多
查看译文
关键词
Dark Matter and Double Beta Decay (experiments)
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要