Gas Absorption and Mass Transfer in a Pore-Array Intensified Tube-in-Tube Microchannel

Transactions of Tianjin University(2020)

引用 1|浏览21
暂无评分
摘要
A pore-array intensified tube-in-tube microchannel (PA-TMC), which is characterized by high throughput and low pressure drop, was developed as a gas–liquid contactor. The sulfite oxidation method was used to determine the oxygen efficiency ( φ ) and volumetric mass transfer coefficient ( k L a ) of PA-TMC, and the mass transfer amount per unit energy ( ε ) was calculated by using the pressure drop. The effects of structural and operating parameters were investigated systematically, and the two-phase flow behavior was monitored by using a charge-coupled device imaging system. The results indicated that the gas absorption efficiency and mass transfer performance of the PA-TMC were improved with increasing pore number, flow rate, and number of helical coil turns and decreasing pore size, row number, annular size, annular length, and surface tension. The φ , ε and k L a of PA-TMC could reach 31.3%, 1.73 × 10 −4 mol/J, and 7.0 s −1 , respectively. The Sherwood number was correlated with the investigated parameters to guide the design of PA-TMC in gas absorption and mass transfer processes.
更多
查看译文
关键词
Pore-array intensified tube-in-tube microchannel (PA-TMCR),Gas–liquid mass transfer,Sulfite oxidation method