Fast and slow water ion populations in the Enceladus plume

JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS(2020)

引用 2|浏览26
暂无评分
摘要
Ion velocities have been measured during the Enceladus E3 and E5 flybys using the Cassini Plasma Spectrometer (CAPS) instrument on the Cassini spacecraft. Data from three sensors in the CAPS instrument have been examined from two flybys that occurred during 2008. Positive ion measurements from the CAPS Ion Beam Spectrometer and Ion Mass Spectrometer have been used to measure positive ion velocities. The CAPS Electron Spectrometer has been used to complement the positive ion findings with measurements of negative ion velocities. Two velocities for the positive ions are found, with the fast ions (2.3-5.8 km/s) originating from the high-speed neutral gas emission and slow ions (0.2-2.2 km/s) associated with the low-speed thermal gas emission from Enceladus. Negative ions were found to be near stationary or northerly traveling, implying a deceleration mechanism within the plume. A tentative detection of fast negative ions was also recorded for one of the flybys. These findings will aid in future modeling of plume dynamics.
更多
查看译文
关键词
slow water ion populations