2D PIV study of flow accelerated corrosion downstream a typical industrial gate valve

Progress in Nuclear Energy(2020)

引用 2|浏览4
暂无评分
摘要
A critical degradation mechanism of piping systems in either nuclear power plant is Flow Accelerated Corrosion (FAC), which causes wall thinning of pipes and component shells from inside. The valves which are frequently used in power plant piping systems are mostly subjected to FAC. A Gate vale in the feed water piping system of a typical nuclear power plant that it’s downstream had been damaged due to the FAC was considered as a reference. In this study the effect of the mean flow velocity and the opening percentage of gate valve on the flow field downstream the valve was investigated by using 2D PIV. The locus where flow turbulences happen downstream the gate valve was determined by 2D PIV. It is found that there is a very good coincidence between the locus in which the maximum wall thinning measured by Ultrasonic Technique (UT) and that the flow turbulences happen downstream the gate valve determined by 2D PIV.
更多
查看译文
关键词
Gate valve,2D PIV,FAC,Wall thinning,UT