Extension Of High Power Deuterium Operation Of Negative Ion Based Neutral Beam Injector In The Large Helical Device

REVIEW OF SCIENTIFIC INSTRUMENTS(2019)

Cited 12|Views67
No score
Abstract
Second deuterium operation of the negative ion based neutral beam injector was performed in 2018 in the large helical device. The electron and ion current ratio improves to I-e/I-acc(D) = 0.31 using the short extraction gap distance of 7mmbetween the plasma grid (PG) and the extraction grid (EG). The strength of the magnetic field by the electron deflection magnet installed in the EG increases by 17% at the PG ingress surface, which effectively reduces the electron component in the negative ion rich plasma in the vicinity of PG apertures. The reduction of the electron current made it possible to operate at a high power arc discharge and beam extraction. Then, the deuterium negative ion current increases to 55.4 A with the averaged current density of 233 A/m(2). The thermal load on the EG using 7 mm gap distance is 0.6 times smaller than the thermal load using a 8 mm gap caused by the reduction of coextracted electron current. The injection beam power increases to 2.9MWin the beam line BL3, and the total beam injection power increases to 7MWby three beam lines in the second deuterium campaign. Published under license by AIP Publishing.