Gantry-Mounted Linear Accelerator-Based Stereotactic Body Radiotherapy for Low- and Intermediate-Risk Prostate Cancer

Advances in Radiation Oncology(2020)

Cited 5|Views100
No score
Abstract
Purpose: To establish the safety and efficacy of gantry-mounted linear accelerator-based stereotactic body radiation therapy (SBRT) for low- and intermediate-risk prostate cancer. Methods: We pooled 921 patients enrolled on 7 single-institution prospective phase II trials of gantry-based SBRT from 2006 to 2017. The cumulative incidences of biochemical recurrence (defined by the Phoenix definition) and physician-scored genitourinary (GU) and gastrointestinal (GI) toxicities (defined per the original trials using Common Terminology Criteria for Adverse Events) were estimated using a competing risk framework. Multivariable logistic regression was used to evaluate the relationship between late toxicity and prespecified covariates: biologically effective dose, every other day versus weekly fractionation, intrafractional motion monitoring, and acute toxicity. Results: Median follow-up was 3.1 years (range, 0.5-10.8 years). In addition, 505 (54.8%) patients had low-risk disease, 236 (25.6%) had favorable intermediate-risk disease, and 180 (19.5%) had unfavorable intermediate-risk disease. Intrafractional motion monitoring was performed in 78.0% of patients. The 3-year cumulative incidence of biochemical recurrence was 0.8% (95% confidence interval [CI], 0-1.7%), 2.2% (95% CI, 0-4.3%), and 5.1% (95% CI, 1.0-9.2%) for low-, favorable intermediate-, and unfavorable intermediaterisk disease. Acute grade >= 2 GU and GI toxicity occurred in 14.5% and 4.6% of patients, respectively. Three-year cumulative incidence estimates of late grade 2 GU and GI toxicity were 4.1% (95% CI, 2.6-5.5%) and 1.3% (95% CI, 0.5-2.1%), respectively, with late grade >= 3 GU and GI toxicity estimates of 0.7% (95% CI, 0.1-1.3%) and 0.4% (95% CI, 0-0.8%), respectively. The only identified significant predictors of late grade >= 2 toxicity were acute grade >= 2 toxicity (P <.001) and weekly fractionation (P <.01), although only 12.4% of patients were treated weekly. Conclusions: Gantry-based SBRT for prostate cancer is associated with a favorable safety and efficacy profile, despite variable intrafractional motion management techniques. These findings suggest that multiple treatment platforms can be used to safely deliver prostate SBRT. (C) 2019 The Authors. Published by Elsevier Inc. on behalf of American Society for Radiation Oncology.
More
Translated text
Key words
stereotactic body radiation therapy,prostate cancer,radiation therapy,gantry-mounted,intermediate-risk
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined