Cocoa powder and catechins as natural mediators to modify carbon-black based screen-printed electrodes. Application to free and total glutathione detection in blood
TALANTA(2020)
摘要
In this work, for the first time, the direct usability of natural products, catechins (CT) and cocoa powder (CO), as electrochemical mediators able to modify a carbon black modified screen-printed electrode (SPE-CB) is proved, and, as proof of applicability, free (GSH) and total glutathione (GSH + GSSG) in blood samples is successfully determined. Noteworthy, the cocoa powder (naturally rich in catechins), dissolved in DMSO, was able to give rise to a useful highly redox-active catechol-quinone surface-confined system onto a carbon black nanoparticles modified screen-printed electrode (SPE-CB-CO - Cocoatrode), giving rise to a similar behaviour obtained with pure catechins (SPE-CB-CT). The electrodeposition process has been carefully studied, the resulting immobilized natural mediator (obtained using both CT and CO) features investigated, and the performance of the resulting sensors (SPE-CB-CT and Cocoatrode) tested and compared. Both modified electrodes (SPE-CB-CT and Cocoatrode) have a good inter-electrodes precision (RSD i(p,a) <= 4.2%, n = 3) and infra-electrodes repeatability (RSD i(p,a) <= 3.9%, n = 20), indicating a robust and stable 'fabrication' strategy. Finally, SPE-CB-CT and Cocoatrode have been employed for the detection of free (GSH) and total (GSH + GSSG) glutathione in blood samples, using differential pulse voltammetry decrease in the mediator's reduction peak (Delta i %), as analytical signal. Analytical curves (R-2 >= 0.998), for the GSH detection, have been determined both with SPE-CB-CT and Cocoatrode in the 2.5 x 10(-8)-6.0 x 10(-5) M and 5.0 x 10(-8)-1.0 x 10(-4) M concentration ranges, respectively. Limits of detections (LODs) were <= 2.6 x 10(-8) M. GSH (free and total) determined in blood samples, by the proposed CT and CO sensors, showed a good intra-electrode repeatability (RSD i(p,a) <= 9.0%, n = 3), with good recoveries (from 88.3% to 117.7%). The values obtained were in agreement with a classical spectrophotometric method (GSH and GSSG concentration relative error between -4.7 and +9.8%). The SPE-CB-CT and the Cocoatrode platforms demonstrated high potentiality in sensing and biosensing scenario, opening new gates to the natural/food products employment as unconventional, eco-friendly and economically affordable analytical active tools.
更多查看译文
关键词
Natural-mediators,Cocoa,Catechins,Nanomaterials,Carbon black,Blood glutathione
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要