Experimental study on VMD and its performance comparison with AGMD for treating copper-containing solution

Chemical Engineering Science(2019)

引用 9|浏览15
暂无评分
摘要
•Copper-containing solution was treated by VMD and AGMD process effectively.•A comprehensive analysis of energy consumption was employed on VMD performance.•The permeate flux and SHEC of VMD achieved 21.82 kg/m2-h and 674.5 kWh/m3.•A stable VMD performance was achieved due to membrane stability.
更多
查看译文
关键词
Copper-containing solution,Vacuum membrane distillation,Air gap membrane distillation,Membrane concentration,Membrane module parameters