Impact of γ-rays and protons on integrated magnetic inductors

2019 Symposium on Design, Test, Integration & Packaging of MEMS and MOEMS (DTIP)(2019)

引用 0|浏览20
暂无评分
摘要
This paper presents the radiation influence on integrated magnetic inductors properties. Characterizations have been performed with an impedance-meter and a vector network analyzer on gamma and proton irradiated inductors. Concerning gamma radiation, characterization has been performed for dose levels comprised between 1 to 100 kGy. The results show that inductors properties have not been modified by γ-rays. For 480 MeV proton radiation, characterization is done with a fluence varying between 2.5 10 10 and 2.5 10 11 p/cm 2 . The results proved an increase of the conductor resistivity by 22% and an increase of the coupling capacitance by a factor of x2 for the considered radiation conditions. On the other hand, the magnetic permeability remains unchanged in our test conditions.
更多
查看译文
关键词
Integrated magnetic inductors,gamma radiation,proton radiation