Chrome Extension
WeChat Mini Program
Use on ChatGLM

Simulation Analysis Of A Ventilation System In A Smart Broiler Chamber Based On Computational Fluid Dynamics

ATMOSPHERE(2019)

Cited 9|Views2
No score
Abstract
In this paper, a CFD (computational fluid dynamics) numerical calculation was employed to examine whether the ventilation system of the self-designed smart broiler house meets the requirements of cooling and ventilation for the welfare in poultry breeding. The broiler chamber is powered by two negative pressure fans. The fans are designed with different frequencies for the ventilation system according to the specific air temperature in the broiler chamber. The simulation of ventilation in the empty chamber involved five working conditions in this research. The simulation of ventilation in the broiler chamber and the simulation of the age of air were carried out under three working conditions. According to the measured dimensions of the broiler chamber, a three-dimensional model of the broiler chamber was constructed, and then the model was simplified and meshed in ICEM CFD (integrated computer engineering and manufacturing code for computational fluid dynamics). Two models, i.e., the empty chamber mesh model and the chamber mesh model with block model, were imported in the Fluent software for calculation. In the experiment, 15 measurement points were selected to obtain the simulated and measured values of wind velocity. For the acquired data on wind velocity, the root mean square error (RMSE) was 19.1% and the maximum absolute error was 0.27 m/s, which verified the accuracy of the CFD model in simulating the ventilation system of the broiler chamber. The boundary conditions were further applied to the broiler chamber model to simulate the wind velocity and the age of air. The simulation results show that, when the temperature was between 32 and 34 degrees C, the average wind velocity on the plane of the corresponding broiler chamber (Y = 0.2 m) was higher than 0.8 m/s, which meets the requirement of comfortable breeding. At the lowest frequency of the fan, the oldest age of air was less than 150 s, which meets the basic requirement for broiler chamber design. An optimization idea is proposed for the age of air analysis under three working conditions to improve the structure of this smart broiler chamber.
More
Translated text
Key words
smart broiler chamber,ventilation system,wind velocity,age of air,computational fluid dynamics,simulation analysis
AI Read Science
Must-Reading Tree
Example
Generate MRT to find the research sequence of this paper
Chat Paper
Summary is being generated by the instructions you defined