Test–retest repeatability of the pattern electroretinogram and flicker electroretinogram

Documenta Ophthalmologica(2019)

引用 5|浏览3
暂无评分
摘要
Purpose To evaluate the repeatability of the steady-state pattern electroretinogram (PERG) and full-field flicker electroretinogram (Flicker ERG) protocols, delivered by the office-based Neuro Optic Vision Assessment (NOVA)™ testing platform, in healthy subjects. Methods Healthy individuals underwent PERG (16° and 24°) and Flicker ERG [fixed luminance (FL) and multi-luminance (ML)] testing protocols. Test–retest repeatability of protocols was calculated using intra-class correlation coefficients (ICC). Reference values of the parameters of the aforementioned tests were also calculated. Results The ICCs for the PERG parameters ranged from 0.793 to 0.911 ( p < 0.001). The ICCs for the Flicker ERG parameters ranged from 0.968 to 0.994 ( p < 0.001). A linear regression analysis was applied to assess the impact of age on ERG responses. Age had a significant impact on all PERG parameters (16° or 24°). The phase response of the FL Flicker ERG significantly decreased with age ( β = − 0.837, p ≤ 0.001). The FL Flicker ERG Magnitude was also impacted with a significant quadratic effect of age ( β = − 0.0047, p = 0.0004). Similarly, the Phase Area Under the Curve (Phase AUC) of the ML Flicker ERG significantly declined with age ( β = − 0.007, p = 0.009), and the impact on the Magnitude AUC was significant as well, with a negative quadratic age effect. Conclusions The PERG and Flicker ERG protocols, delivered by an office-based testing platform, were shown to have good-to-excellent test–retest repeatability when tests were performed in the same order and in immediate succession.
更多
查看译文
关键词
Steady-state pattern electroretinogram, Flicker electroretinogram, Repeatability, Electrophysiology, Reference database
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要