Evaluation of a motion-robust 2D chemical shift-encoded technique for R2* and field map quantification in ferumoxytol-enhanced MRI of the placenta in pregnant rhesus macaques.

JOURNAL OF MAGNETIC RESONANCE IMAGING(2020)

引用 9|浏览59
暂无评分
摘要
Background 3D chemical shift-encoded (CSE)-MRI techniques enable assessment of ferumoxytol concentration but are unreliable in the presence of motion. Purpose To evaluate a motion-robust 2D-sequential CSE-MRI for R2* and B0 mapping in ferumoxytol-enhanced MRI of the placenta. Study Type Prospective. Animal Model Pregnant rhesus macaques. Field Strength/Sequence 3.0T/CSE-MRI. Assessment 2D-sequential CSE-MRI was compared with 3D respiratory-gated CSE-MRI in placental imaging of 11 anesthetized animals at multiple timepoints before and after ferumoxytol administration, and in ferumoxytol phantoms (0 mu g/mL-440 mu g/mL). Motion artifacts of CSE-MRI in 10 pregnant women without ferumoxytol administration were assessed retrospectively by three blinded readers (4-point Likert scale). The repeatability of CSE-MRI in seven pregnant women was also prospectively studied. Statistical Tests Placental R2* and boundary B0 field measurements (Delta B0) were compared between 2D-sequential and 3D respiratory-gated CSE-MRI using linear regression and Bland-Altman analysis. Results In phantoms, a slope of 0.94 (r(2) = 0.99, concordance correlation coefficient rho = 0.99), and bias of -4.8 s(-1) (limit of agreement [LOA], -41.4 s(-1), +31.8 s(-1)) in R2*, and a slope of 1.07 (r(2) = 1.00, rho = 0.99) and bias of 11.4 Hz (LOA -12.0 Hz, +34.8 Hz) in Delta B0 were obtained in 2D CSE-MRI compared with 3D CSE-MRI for reference R2* <= 390 s(-1). In animals, a slope of 0.92 (r(2) = 0.97, rho = 0.98) and bias of -2.2 s(-1) (LOA -55.6 s(-1), +51.3 s(-1)) in R2*, and a slope of 1.05 (r(2) = 0.95, rho = 0.97) and bias of 0.4 Hz (LOA -9.0 Hz, +9.7 Hz) in Delta B0 were obtained. In humans, motion-impaired R2* maps in 3D CSE-MRI (Reader 1: 1.8 +/- 0.6, Reader 2: 1.3 +/- 0.7, Reader 3: 1.9 +/- 0.6), while 2D CSE-MRI was motion-free (Reader 1: 2.9 +/- 0.3, Reader 2: 3.0 +/- 0, Reader 3: 3.0 +/- 0). A mean difference of 0.66 s(-1) and coefficient of repeatability of 9.48 s(-1) for placental R2* were observed in the repeated 2D CSE-MRI. Data Conclusion 2D-sequential CSE-MRI provides accurate R2* and B0 measurements in ferumoxytol-enhanced placental MRI of animals in the presence of respiratory motion, and motion-robustness in human placental imaging. Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2020;51:580-592.
更多
查看译文
关键词
placenta,ferumoxytol,chemical shift-encoded,R2*,B0 field,motion-robust
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要