针对某燃煤电厂水冷壁管出现的尿素腐蚀问题,在高压釜中模拟电厂现场运行工况,研究了尿素在高温条件下对水冷壁管15CrMo钢的腐蚀特性.在270℃、5个尿素浓度(70,140,280,560和840mg/L)下进行了高温分解实验与挂片实验,同时进行了典型浓度280mg/L、270℃条件下定时分解实验,测定了实验中汽、液样品的TOC值与红外吸收光谱,用电化学方法与微观表征技术(SEM,EDS和XRD)研究了尿素分解残液对15CrMo钢的腐蚀特性.结果表明:尿素在分解过程中会产生腐蚀性离子NH2COO-而对水冷壁管产生腐蚀,且15CrMo钢的腐蚀速率随尿素浓度的增大而加快,最大腐蚀速率达0.593 mm/a.消除脱硝系统的局部设计缺陷可以有效防止尿素对水冷壁管的腐蚀.