Automated Generation of High-Order Modes for Tests of Quasi-Optical Systems of Gyrotrons for W7-X Stellarator

T. Ruess,K. A. Avramidis,G. Gantenbein,Z. Ioannidis,S. Illy, J. Jin, F.-C. Lutz,A. Marek, S. Ruess, T. Rzesnicki,M. Thumm,D. Wagner, J. Weggen,J. Jelonnek

2019 12th German Microwave Conference (GeMiC)(2019)

引用 1|浏览14
暂无评分
摘要
A test system for the verification of the quasi-optical converter system is vital in the gyrotron development. For this reason, an automated measurement setup has been developed and is benchmarked with the TE 28,8 mode operating in the cavities of the gyrotrons of W7-X with a high purity of about 95 % and a counter-rotating amount of about 0.3 %. The time duration for the mode generator adjustment has been reduced to two days for this mode. After a successful mode excitation, the quasi-optical mode converter, consisting of a launcher and three mirrors, is measured having a vectorial Gaussian mode content of 97 %.