Design Analysis Of A High-Q Micromechanical Capacitive Accelerometer System

IEICE ELECTRONICS EXPRESS(2017)

引用 3|浏览16
暂无评分
摘要
A micromechanical capacitive accelerometer system is analyzed in this paper, which includes a high-Q sensing element and a high-order switched-capacitor (SC) sigma-delta Sigma Delta CMOS interface circuit. The high-Q high-order topology obtained a sub-mu g/v root Hz noise floor. The loop stability is implemented by the operation of electrostatic feedback force, heavy phase compensation and the off-chip adjusting of distributed-feedback factors. The interface circuit is implemented in a standard 0.5 mu m CMOS process. The system consumes 12mW from a single 5V supply with the noise level of lower than 400 ng/v root Hz. The system bandwidth is 600 Hz and the input range of the accelerometer is +/- 0.7 g. The measured sensitivity of 2.5V/g is achieved.
更多
查看译文
关键词
accelerometer, high-Q, interface circuit