Design and test of 704 MHz and 2.1 GHz normal conducting cavities for low energy RHIC electron cooler

PHYSICAL REVIEW ACCELERATORS AND BEAMS(2019)

引用 8|浏览3
暂无评分
摘要
The low energy RHIC electron cooler (LEReC) is currently under commissioning at BNL to improve RHIC luminosity for heavy ion beam energies below 10 GeV/nucleon. The linac of LEReC consists of a dc photoemission gun, one 704 MHz superconducting radio frequency booster cavity, and three normal conducting cavities. It is designed to deliver a 1.6-2.6 MeV electron beam, with peak-to-peak momentum spread dp/p of less than +/- 7 x 10(-4). Two of the three normal conducting cavities will be used in LEReC for energy spread correction: a single-cell 704 MHz cavity for energy dechirping and a three-cell 2.1 GHz third harmonic cavity for rf curvature correction. In this paper, we present the designs and rf test results of these two cavities.