Development of radiation tolerant components for the Quench Protection System at CERN

JOURNAL OF INSTRUMENTATION(2016)

Cited 2|Views4
No score
Abstract
This paper describes the results of irradiation campaigns with the high resolution Analog to Digital Converter (ADC) ADS1281. This ADC will be used as part of a revised quench detection circuit for the 600 A corrector magnets at the CERN Large Hadron Collider (LHC). To verify the radiation tolerance of the ADC an irradiation campaign using a proton beam, applying doses up to 3,4 kGy was conducted. The resulting data and an analysis of the found failure modes is discussed in this paper. Several mitigation measures are described that allow to reduce the error rate to levels acceptable for operation as part of the LHC QPS.
More
Translated text
Key words
Radiation-hard electronics,Data acquisition circuits,Data acquisition concepts