The D0 Run II Impact Parameter Trigger

T. Adams,Q. An,K. M. Black,T. Bose,N. J. Buchanan,S. Caron,D. K. Cho,S. Choi,A. Das,M. Das,H. Dong,W. Earle, H. Evans,S. N. Fatakia, L. Feligioni,T. Fitzpatrick,E. Hazen, U. Heintz,K. Herner,J. D. Hobbs,D. Khatidze,W. M. Lee,S. L. Linn,M. Narain,C. Pancake, N. Parashar,E. Popkov,H. B. Prosper,G. Redner, M. P. Sanders, S. Sengupta, B. Smart, L. Sonnenschein,G. Steinbruck, W. Taylor, S. Ansermet-Tentindo,H. D. Wahl,T. Wijnen,J. Wittlin, J. Wu,S. X. Wu, A. Zabi, J. Zhu

Nuclear Instruments & Methods in Physics Research Section A-accelerators Spectrometers Detectors and Associated Equipment(2007)

引用 23|浏览31
暂无评分
摘要
Many physics topics to be studied by the D0 experiment during Run II of the Fermilab Tevatron ppbar collider give rise to final states containing b--flavored particles. Examples include Higgs searches, top quark production and decay studies, and full reconstruction of B decays. The sensitivity to such modes has been significantly enhanced by the installation of a silicon based vertex detector as part of the DO detector upgrade for Run II. Interesting events must be identified initially in 100-200 microseconds to be available for later study. This paper describes custom electronics used in the DO trigger system to provide the real--time identification of events having tracks consistent with the decay of b--flavored particles.
更多
查看译文
关键词
top quark,real time
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要