Characterization of the STS/MUCH-XYTER2, a 128-channel time and amplitude measurement IC for gas and silicon microstrip sensors

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2018)

引用 21|浏览29
暂无评分
摘要
New physics experiments at the Facility for Antiproton and Ion Research (FAIR) in Darmstadt require application-optimized detector readout circuits. The STS/MUCH-XYTER2 (or SMX2) is a new, 128-channel prototype ASIC for silicon strip detectors and gas electron multiplier (GEM) detectors in the Compressed Baryonic Matter (CBM) experiment. It provides self-triggered amplitude and time measurement of incoming charge and serial streaming of digitized data. The 10 mm × 6.75 mm chip was fabricated employing the UMC CMOS 180 nm process. It comprises of an analog front-end with dual-path processing including a timing comparator in one path and a continuous-time 5-bit analog-to-digital converter in the other path, a digital back-end with time pre-sorting, advanced monitoring and throttling features and multiple 320 Mbps, serial links targeted for a GBT-based data acquisition structure. Specific conditions of the detector systems will be discussed prior to the structure and the features of the ASIC together with measurement results.
更多
查看译文
关键词
Front-end electronics for detector readout,Particle tracking detectors,Muon detector,Gaseous detectors,Silicon detectors