A high angular resolution silicon microstrip telescope for crystal channeling studies

G. Hall, G. Auzinger,J. Borg,T. James,M. Pesaresi, M. Raymond

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2019)

引用 9|浏览15
暂无评分
摘要
A charged particle telescope has been deployed for data taking at high rates in a CERN beam line using protons and other particles. The apparatus has a baseline of approximately 10 m in each arm, and achieves an angular resolution of 5.4 μrad using 400 GeV/c protons. The electronic readout and data acquisition system is based on that developed for the CMS Tracker, and provides almost deadtime-free operation at trigger rates of up to about 10 kHz.
更多
查看译文
关键词
ASIC electronics,Tracking detectors,Silicon microstrips,Crystal channeling