Research On Uniaxial Tension Test Of Brain Tissue

Feng Zhao,Jun Zhou, Di Sang, Xutao Zhang, Min-fa Zhou,Ding Wang

3RD INTERNATIONAL CONFERENCE ON APPLIED MECHANICS AND MECHANICAL AUTOMATION (3RD AMMA 2017)(2017)

引用 0|浏览4
暂无评分
摘要
Corresponding to low targeting accuracy due to tissue deformation during the process of electrode insertion in sub-thalamic nucleus deep brain stimulation (DBS), biomechanical properties of brain tissue are essential to investigate. In this paper the isolated porcine brain tissue is used in the uniaxial tensile test. Moreover, cylindrical samples of diameter (10 mm) and height (10 mm) are used to measure tensile length by single degree of axis at 5mm/s, until specimen was broken. The stretch ratio of brain tissue has been explored. The material failure criterion parameters, K, Gamma(1), Gamma(2), of MAT-QUASILINEAR-VISCOELASTIC biological material model in LS-DYNA are fitting calculated according to the experimental results. Six uniaxial failure data obtained from uniaxial tests are 4.81, 5.00, 4.07, 4.62, 4.28, 4.45 respectively. Three failure material constants Gamma(1), Gamma(2), K are -0.0084, -3.1944, -4.8095. The failure criterion is being implemented in LS-DYNA to simulate brain tissue.
更多
查看译文
关键词
LS-DYNA, Stretch ratio, Failure criterion
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要