Design and Test of Wendelstein 7-X Water-Cooled Divertor Scraper
IEEE Transactions on Plasma Science(2018)
摘要
Heat load calculations have indicated the possible overloading of the ends of the water-cooled divertor facing the pumping gap beyond their technological limit. The intention of the scraper is the interception of some of the plasma fluxes both upstream and downstream before they reach the divertor surface. The scraper is divided into six modules of four plasma facing components (PFCs); each module...
更多查看译文
关键词
Prototypes,Welding,Temperature measurement,Heating systems,Plasma temperature,Cooling
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要