Andrew Blue, A. Affolder,X. Ai,P. P. Allport,J.-H. Arling,Ryan Justin Atkin, Lucrezia Stella Bruni,Ina Carli,G. Casse,L. Chen,A. S. Chisholm,Kyle James Read Cormier,W. Cunningham,P. Dervan,S. Diez, Z. Dolezal, J. Dopke,Etienne Dreyer,J. Dreyling-Eschweiler,C. Escobar,Veronica Fabiani, V. Fadeyev,J. Fernandez-Tejero,C. Fleta,A. Gabrielli, B. J. Gallop,C. García Argos,A. Greenall,I. M. Gregor, G. Greig, F. Guescini, K. Hara,M. Hauser,Y. Huang,R. F. H. Hunter, J. S. Keller, C.T. Klein, P. Kodys, U. Koetz,T. Koffas, Z. Kotek,J. Kroll,S. Kühn,Shih-Chang Lee,Y. Liu,K. Lohwasser, L. Mészárosová,M. Mikestikova,M. Miñano Moya,R. Mori,B. Moser, K. Nikolopoulos, R. Peschke, G. Pezzullo,P. W. Phillips, L. Poley, M. Queitsch-Maitland,F. Ravotti,D. Rodriguez,E. Rossi,A. Rummler, C. Sawyer,Dennis Sperlich, S. Sullivan, J. Suzuki, M. Sykora,Elvedin Tahirovic, O. Theiner,J. P. Thomas, Y. Unno,S. Wada, M. Warren,M. Wiehe, S. Wonsak, M. Wormald, K. Wraight,Nataliia Zakharchuk,H. Zhu

Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment(2019)

引用 3|浏览78
暂无评分
摘要
The planned High Luminosity Large Hadron Collider is being designed to maximise the physics potential of the LHC with 10 years of operation at instantaneous luminosities of 7.5×1034cm−2s−1. A consequence of this increased luminosity is the expected radiation damage requiring the tracking detectors to withstand hadron fluence to over 1×1015 1 MeV neutron equivalent per cm2 in the ATLAS Strips system. Fast readout electronics, deploying 130 nm CMOS front-end electronics are glued on top of a silicon sensor to make a module. The radiation hard n-in-p micro-strip sensors used have been developed by the ATLAS ITk Strip Sensor collaboration and produced by Hamamatsu Photonics. A series of tests were performed at the DESY-II test beam facility to investigate the detailed performance of a strip module with both 2.5 cm and 5 cm length strips before irradiation. The DURANTA telescope was used to obtain a pointing resolution of 2 μm, with an additional pixel layer installed to improve timing resolution to ∼25 ns. Results show that prior to irradiation a wide range of thresholds (0.5–2.0 fC) meet the requirements of a noise occupancy less than 1×10−3 and a hit efficiency greater than 99%.
更多
查看译文
关键词
Semiconductor,Silicon,Detector
AI 理解论文
溯源树
样例
生成溯源树,研究论文发展脉络
Chat Paper
正在生成论文摘要